HAMILTON-C3

Home Our Products HAMILTON-C3

Authorized Seller in North India

HAMILTON-C3 Ventilator
HAMILTON-C3 thumbnail 1 HAMILTON-C3 thumbnail 2 HAMILTON-C3 thumbnail 3

HAMILTON-C3: The Compact High-End Ventilator

The HAMILTON-C3 is a compact yet high-end ICU ventilator designed to deliver reliable and versatile ventilation therapy across various patient groups. Its integrated turbine provides independence from compressed air, making it ideal for flexible use within the hospital.

With an intuitive user interface and a comprehensive set of ventilation modes, the HAMILTON-C3 ensures efficient and patient-adaptive care. Its focus on portability and ease of use makes it a valuable asset for busy clinical environments.

Key Features

Compact & High-End

Combines high performance with a space-saving design.

Integrated Turbine

Provides independence from compressed air, increasing mobility.

Battery Operation

Allows uninterrupted operation during transport or power outages.

Universal User Interface

Consistent operation across Hamilton ventilators, reducing training time.

Intelligent Ventilation Modes

Includes ASV® and INTELLiVENT®-ASV® for adaptive and automated patient care.

Advanced Monitoring

Comprehensive tools for real-time patient data and lung mechanics.

Designed for Versatility

Versatile Setup Options C3

Wherever You Need Me: Turbine-Driven for More Flexibility

The HAMILTON-C3 is truly portable thanks to its powerful, integrated turbine. This eliminates the need for a compressed air supply, providing maximum flexibility and mobility within the hospital, whether it’s in the ICU, recovery room, or for intrahospital transport.

Transport Solutions

Know One, Know Them All: A Universal User Interface

Universal User Interface C3

Streamlined Operation Across All Hamilton Medical Ventilators

The universal user interface of Hamilton Medical ventilators, including the HAMILTON-C3, ensures consistent and intuitive operation across your entire fleet. This significantly reduces training time and minimizes the potential for errors, allowing clinicians to seamlessly transition between devices.

The integrated "Ventilation Cockpit" visually presents complex patient data, enabling quick and informed decisions, and optimizing the clinical workflow.

Hamilton Ventilators

Optimized for Patient & Clinician

For Your Patients: Superior Care

  • ASV® - Adaptive Support Ventilation®: Automatically adapts ventilation to patient's lung mechanics and effort, promoting patient comfort and weaning readiness.
  • Early Mobilization Support: Features designed to facilitate patient mobility and aid in early rehabilitation.
  • High Flow Nasal Cannula Therapy: Provides comfortable oxygen delivery as an integrated option.
  • Integrated Nebulizer: For efficient and synchronized aerosol drug delivery.

For You, the Clinician: Efficiency & Control

  • Less Knob-Turning, More Automation: INTELLiVENT-ASV (optional) reduces manual adjustments, freeing up clinicians for other critical tasks.
  • On-Screen Troubleshooting: Instant, clear guidance for alarm resolution and operational issues directly on the display.
  • Comprehensive Learning Paths: Access to Hamilton Medical's online Academy for continuous education and product familiarity.
  • Constant Evolution: Receive new features and improvements to existing ones throughout the ventilator's lifetime.

Technical Specifications

Patient Groups:

Adult, Pediatric, Neonatal

Dimensions (W x D x H):

Ventilation unit: 320 x 300 x 395 mm
Unit with trolley: 1320 x 590 x 780 mm

Weight:

Ventilation unit: 15.5 kg (34.2 lb)
Trolley (optional): 21 kg (46.3 lb)

Display:

12.1-inch color TFT touchscreen

Battery Operating Time:

Typically 2.5 h (with one battery), up to 5 h (with two batteries)

Air Supply:

Integrated turbine; independent from compressed air

O2 connector:

DISS or NIST

Connectivity:

RS-232, USB, Ethernet, Nurse call

Loudness:

Typically 35 dB (A) in normal operation

Ventilation Modes and Therapies

Volume controlled, flow controlled

Standard feature for precise volume delivery.

Volume targeted, adaptive pressure controlled

Ensures optimal tidal volume with adaptive pressure support.

Intelligent ventilation

ASV®, INTELLiVENT®-ASV® available for enhanced automation.

Noninvasive ventilation

Standard mode for non-invasive respiratory support.

High flow nasal cannula therapy

Standard feature for comfortable high-flow oxygen delivery.

Advanced Monitoring

Visualization of lung mechanics (Dynamic Lung)

Standard feature providing real-time graphical representation of lung function.

Visualization of patient’s ventilator dependence

Standard visual tool to assess weaning readiness.

Esophageal pressure measurement

Standard for precise pressure monitoring within the esophagus.

Capnography

Standard CO2 monitoring for ventilation quality assessment.

SpO2 monitoring

Standard pulse oximetry for blood oxygen saturation levels.

Other Ventilation Features

Recruitability assessment and lung recruitment (P/V Tool Pro)

Standard tool for assessing lung recruitability and optimizing recruitment strategy.

Patient-ventilator synchronization (IntelliSync+)

Standard feature for real-time detection of patient efforts to enhance synchrony.

CPR ventilation

Standard feature for emergency ventilation during CPR.

Hamilton Connect Module

Standard module for enhanced connectivity and data integration.

Hamilton Connect App

Standard mobile application for remote monitoring and control.

For the Complete Solution: Fully Integrated Accessories

HAMILTON-H900 humidifier

HAMILTON-H900 Humidifier

Seamlessly integrates for optimal respiratory gas conditioning. ( Standard)

IntelliCuff cuff pressure controller

IntelliCuff Cuff Pressure Controller

Automatically maintains optimal cuff pressure to prevent leaks and injury. ( Standard)

Pneumatic and Aerogen nebulizers

Pneumatic & Aerogen Nebulizers

Integrated pneumatic nebulizer ( Standard), Aerogen nebulizer ( Standard).

SpO2 and CO2 sensors

SpO2 and CO2 Sensors

Accurate and real-time patient monitoring for vital respiratory parameters. ( Standard)

Sedaconda ACD-S

Compatibility with Sedaconda ACD-S

Seamless integration with anesthetic delivery system. ( Standard)

Our Authorised Channel Partners

Hamilton Medical Logo

Hamilton Medical

Switzerland

Fresenius Kabi Logo

Fresenius Kabi

Germany

ResMed Logo

ResMed

Australia

Aerogen Logo

Aerogen

Ireland

Related Products

Hamilton-C6 Ventilator

Hamilton-C6

Next generation intelligent ICU ventilator.

View Product
HAMILTON-G5/S1 Ventilator

Hamilton-G5/S1

High-end modular ICU ventilator.

View Product
Hamilton-T1 Ventilator

Hamilton-T1

Compact transport and critical care.

View Product
Gulmohar Nuvitron G2 Patient Monitor

Gulmohar Nuvitron G2

Comprehensive vital sign monitoring.

View Product